Skip to content
DOUBLEDYN · TRANSPARENCY

Methodology note

Version 1.1 · Reviewed on 2026-08-03 · under continuous validation — Electricity: MCTI 2025 (explicit base year). For a formal inventory, use the factor for the reporting year (e.g. 2024 → 0.0545).

Tool positioning

The DoubleDyn calculator is a SCREENING and ESTIMATED ASSESSMENT tool: it converts user-reported operational data into an estimated GHG footprint (tCO₂e/year), with a +15% safety margin.

It does NOT replace a formal GHG inventory under GHG Protocol / ISO 14064 or serve as a basis for regulatory reporting (SBCE/CVM) without the Enterprise plan, which applies the complete methodology with validated data.

The aim is to provide a reliable starting point for prioritizing reduction and offsetting actions, with full transparency about how every figure is calculated.

Alignment with initiatives and regulation

  • GHG Protocol — methodological basis for inventories (scopes 1, 2 and 3). ghgprotocol.org ↗
  • SBTi — the DoubleDyn inventory (structured scopes 1+2) is compatible with the reporting requested by clients whose targets have been validated by the Science Based Targets initiative. sciencebasedtargets.org ↗ (DoubleDyn does not issue or validate SBTi targets; validation is the initiative's formal process)
  • SBCE (Law 15.042/2024) — data structure ready for mandatory emissions reporting in the Brazilian Emissions Trading System. official text ↗
  • ISO 14064-1 — principles for organization-level GHG quantification and reporting (structural reference, not inventory certification).

Scope coverage (GHG Protocol)

Reported dataScopeNote
LPG, natural gas, generator diesel, firewoodScope 1Direct stationary combustion
Petrol, diesel, CNG (fleet)Scope 1Direct mobile combustion
Grid-purchased electricityScope 2Location-based method, SIN average factor (MCTI)
Refrigeration (refrigerant gases)Scope 1 (leaks)Estimate by system size
Business air travelScope 3Average domestic/international distances
Water, paper, waste (disposal)Scope 3Value chain — simplified for screening
Ethanol (fleet)Neutral (bio)Factor 0 — biofuel (life-cycle analysis not included)

Emission factors

FactorValueUnitReferenceStatus
Electricity (grid — annual average factor)0,0461tCO₂/MWhMCTI — Fator Médio Anual do SIN (inventários corporativos) (2025)OFFICIAL
LPG2,983kgCO₂/kgIPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006)OFFICIAL
Natural gas2,07kgCO₂/m³IPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006)OFFICIAL
Diesel (generator)2,603kgCO₂/litreIPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006)OFFICIAL
Petrol2,212kgCO₂/litreIPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006)OFFICIAL
CNG2,07kgCO₂/m³IPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006)OFFICIAL
Firewood1460kgCO₂/tonneIPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) — madeira seca ao ar (2006)OFFICIAL
Ethanol0kgCO₂/litreIPCC 2006 — CO₂ biogênico não contabilizado (2006)OFFICIAL
Domestic air travel0,10974kgCO₂/km/passengerDEFRA 2024 — short-haul (sem RF), gov.uk GHG Conversion Factors (2024)OFFICIAL
International air travel0,10377kgCO₂/km/passengerDEFRA 2024 — International (não-UK, sem RF), gov.uk GHG Conversion Factors (2024)OFFICIAL
Water0,33885kgCO₂/m³DEFRA 2024 — water supply (0,15311) + water treatment (0,18574), gov.uk (2024)OFFICIAL
Paper3,134kgCO₂/resmaDEFRA 2024 — paper and board: paper (1.339,32 kgCO₂/t) × 2,34 kg/resma A4 75g (2024)OFFICIAL
Air conditioning0,05tCO₂/unidade/anoEstimativa operacionalESTIMATE
Refrigeration (leaks)0 / 0.5 / 2 / 5tCO₂/yearEstimate by sizeESTIMATE
Waste (landfill)0,497tCO₂/tonneDEFRA 2024 — refuse: household residual waste → aterro (497,04 kgCO₂/t, gate-to-grave), gov.uk (2024)OFFICIAL
Hazardous waste1,2kgCO₂/kgEstimate — to be validated (Round 2: full DEFRA/CETESB set)TO BE VALIDATED
METANO_ENTERIC1,6tCO₂e/cabeça/anoIPCC 2006/2019 Tier 1 — fermentação entérica bovina (56–64 kg CH₄/cab/ano × GWP 28) (2006)TO BE VALIDATED
N2O_FERTILIZANTE0,00416tCO₂e/kg NIPCC 2006 Tier 1 — N₂O de fertilizantes nitrogenados (EF 0,01 kg N₂O-N/kg N × 44/28 × GWP 265) (2006)TO BE VALIDATED
QUEIMA_RESIDUOS_AGRO0,003tCO₂e/tonelada queimadaIPCC 2006 Tier 1 — queima de resíduos agrícolas (CH₄ + N₂O; CO₂ biogênico não contabilizado) (2006)TO BE VALIDATED
REFRIG_COMERCIAL0,35tCO₂e/unidade/anoGWP R-410A DEFRA 2024 (1.924 kgCO₂e/kg, AR5) × carga ~1,2 kg × fuga anual 15% ≈ 0,35 t — premissas documentadas (2024)OFFICIAL

Table generated automatically from the single source of factors (factors.js), the same values used by the calculator. Factors marked “to be validated” or “estimate” will be validated in Round 2.

Calculation formulas

Energy (Scopes 1 + 2)
∑ consumption × factor × 12 months. Electricity: kWh/1000 × factor × 12. Renewable sources: solar/wind × 0.05; biomass × 0.15; mixed × 0.55.
Fleet (Scope 1)
∑ litres/m³ × factor/1000 × 12. Air travel: number of trips × average km (1500 domestic / 8000 international) × factor / 1000.
Facilities
Water: m³ × 0.708/1000 × 12 × on-site factor. Air conditioning: number × 0.05 × on-site factor. Refrigeration: size-based table. Paper: reams × 3.0/1000 × 12 × on-site factor. On-site factor = 1 − (remote work % × 0.7).
Waste
Landfill: tonnes × (1 − recycling %) × 0.5 × 12. Hazardous: kg × 1.2/1000 × 12.
Total
Base = energy + fleet + facilities + waste. Total = base × 1.15 (15% safety margin for estimate uncertainty).
Exposure cost (reference)
R$ 8,500 + (total tCO₂e × R$ 120): a report reference value for prioritization, not a market quote.

The +15% safety margin is applied to the sum of categories to account for the uncertainty inherent in screening estimates.

DQS — DoubleDyn Quality Score

DQS (DoubleDyn Quality Score, 0–1000) is the proprietary indicator of an operation's environmental evidence quality, completeness and traceability, from event to project. Four weighted criteria (total = 1000): the more complete and verifiable the evidence, the higher the score. This is neither regulatory nor third-party certification; it is DoubleDyn's transparency layer over what was measured and evidenced.

  1. Documented weights: Registry 300 points (30%) · Evidence 250 points (25%) · Data 250 points (25%) · Methodology 200 points (20%)
  2. Registry (0–300): verifiable public evidence — on-chain retirement in the beneficiary's name + DD-CERT certificate with QR and serial (300) · on-chain retirement without a certificate (200) · off-chain retirement receipt (80)
  3. Evidence (0–250): documentation for every figure — complete dossier with original procurement, contract and reports (250) · partial documents with specific gaps (150) · undocumented figures (30)
  4. Data (0–250): actual measurement vs estimates — measured primary data (bills, telemetry, volume estimation) (250) · estimate with documented assumptions (150) · sector/CNAE proxy estimate (80)
  5. Methodology (0–200): method and factors from official sources — documented GHG Protocol + MCTI/SIRENE, DEFRA, IPCC factors (200) · proprietary method without external references (100) · no declared method (0)
  6. Confidence factor: proxy-estimated data (CNAE) applies 0.92, an 8% methodological uncertainty penalty
  7. DQS = (registry + evidence + data + methodology) × confidence factor, capped between 0 and 1000
  8. Calculator Quick Scan: the preview uses only Data + Methodology (maximum 450) and is labelled self-declared. An operation's official DQS requires actual evidence and records and is granted after execution.
SealDQS range
Gold≥ 751
Silver401 – 750
Bronze≤ 400

Sector benchmarks (intensity)

Average intensity in tCO₂e per R$ 1 million of annual revenue, by sector. Based on public national inventory data (SEEG / GHG Protocol Brazil).

SectorIntensity (tCO₂e/R$ million)
Agriculture120
Mining180
Industry85
Logistics110
Construction75
Services12
Retail and trade25
Other60

Limitations

  • Estimates based on national averages and sector benchmarks may differ from the company's specific circumstances.
  • Scopes and factors are simplified for screening; Scope 3 classification is approximate.
  • Does not replace a formal inventory (GHG Protocol / ISO 14064) or regulatory reporting (SBCE/CVM).
  • The +15% margin covers estimate uncertainty, not errors in reported data.
  • Factors are reviewed periodically; version and review date are published above.

under continuous validation — Electricity: MCTI 2025 (explicit base year). For a formal inventory, use the factor for the reporting year (e.g. 2024 → 0.0545).

← Back to the calculator
YOUR PRIVACY

No advertising cookies in this preview. Your choice lasts up to 180 days and can be changed in the footer. Accepting cookies does not authorize commercial contact.

Read privacy policy →
Methodology note — How we calculate GHG emissions | DoubleDyn