Methodology note
Version 1.1 · Reviewed on 2026-08-03 · under continuous validation — Electricity: MCTI 2025 (explicit base year). For a formal inventory, use the factor for the reporting year (e.g. 2024 → 0.0545).
Tool positioning
The DoubleDyn calculator is a SCREENING and ESTIMATED ASSESSMENT tool: it converts user-reported operational data into an estimated GHG footprint (tCO₂e/year), with a +15% safety margin.
It does NOT replace a formal GHG inventory under GHG Protocol / ISO 14064 or serve as a basis for regulatory reporting (SBCE/CVM) without the Enterprise plan, which applies the complete methodology with validated data.
The aim is to provide a reliable starting point for prioritizing reduction and offsetting actions, with full transparency about how every figure is calculated.
Alignment with initiatives and regulation
- GHG Protocol — methodological basis for inventories (scopes 1, 2 and 3). ghgprotocol.org ↗
- SBTi — the DoubleDyn inventory (structured scopes 1+2) is compatible with the reporting requested by clients whose targets have been validated by the Science Based Targets initiative. sciencebasedtargets.org ↗ (DoubleDyn does not issue or validate SBTi targets; validation is the initiative's formal process)
- SBCE (Law 15.042/2024) — data structure ready for mandatory emissions reporting in the Brazilian Emissions Trading System. official text ↗
- ISO 14064-1 — principles for organization-level GHG quantification and reporting (structural reference, not inventory certification).
Scope coverage (GHG Protocol)
| Reported data | Scope | Note |
|---|---|---|
| LPG, natural gas, generator diesel, firewood | Scope 1 | Direct stationary combustion |
| Petrol, diesel, CNG (fleet) | Scope 1 | Direct mobile combustion |
| Grid-purchased electricity | Scope 2 | Location-based method, SIN average factor (MCTI) |
| Refrigeration (refrigerant gases) | Scope 1 (leaks) | Estimate by system size |
| Business air travel | Scope 3 | Average domestic/international distances |
| Water, paper, waste (disposal) | Scope 3 | Value chain — simplified for screening |
| Ethanol (fleet) | Neutral (bio) | Factor 0 — biofuel (life-cycle analysis not included) |
Emission factors
| Factor | Value | Unit | Reference | Status |
|---|---|---|---|---|
| Electricity (grid — annual average factor) | 0,0461 | tCO₂/MWh | MCTI — Fator Médio Anual do SIN (inventários corporativos) (2025) | OFFICIAL |
| LPG | 2,983 | kgCO₂/kg | IPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006) | OFFICIAL |
| Natural gas | 2,07 | kgCO₂/m³ | IPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006) | OFFICIAL |
| Diesel (generator) | 2,603 | kgCO₂/litre | IPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006) | OFFICIAL |
| Petrol | 2,212 | kgCO₂/litre | IPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006) | OFFICIAL |
| CNG | 2,07 | kgCO₂/m³ | IPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) (2006) | OFFICIAL |
| Firewood | 1460 | kgCO₂/tonne | IPCC 2006 Guidelines, Vol.2 Cap.2 (Table 2.2) — madeira seca ao ar (2006) | OFFICIAL |
| Ethanol | 0 | kgCO₂/litre | IPCC 2006 — CO₂ biogênico não contabilizado (2006) | OFFICIAL |
| Domestic air travel | 0,10974 | kgCO₂/km/passenger | DEFRA 2024 — short-haul (sem RF), gov.uk GHG Conversion Factors (2024) | OFFICIAL |
| International air travel | 0,10377 | kgCO₂/km/passenger | DEFRA 2024 — International (não-UK, sem RF), gov.uk GHG Conversion Factors (2024) | OFFICIAL |
| Water | 0,33885 | kgCO₂/m³ | DEFRA 2024 — water supply (0,15311) + water treatment (0,18574), gov.uk (2024) | OFFICIAL |
| Paper | 3,134 | kgCO₂/resma | DEFRA 2024 — paper and board: paper (1.339,32 kgCO₂/t) × 2,34 kg/resma A4 75g (2024) | OFFICIAL |
| Air conditioning | 0,05 | tCO₂/unidade/ano | Estimativa operacional | ESTIMATE |
| Refrigeration (leaks) | 0 / 0.5 / 2 / 5 | tCO₂/year | Estimate by size | ESTIMATE |
| Waste (landfill) | 0,497 | tCO₂/tonne | DEFRA 2024 — refuse: household residual waste → aterro (497,04 kgCO₂/t, gate-to-grave), gov.uk (2024) | OFFICIAL |
| Hazardous waste | 1,2 | kgCO₂/kg | Estimate — to be validated (Round 2: full DEFRA/CETESB set) | TO BE VALIDATED |
| METANO_ENTERIC | 1,6 | tCO₂e/cabeça/ano | IPCC 2006/2019 Tier 1 — fermentação entérica bovina (56–64 kg CH₄/cab/ano × GWP 28) (2006) | TO BE VALIDATED |
| N2O_FERTILIZANTE | 0,00416 | tCO₂e/kg N | IPCC 2006 Tier 1 — N₂O de fertilizantes nitrogenados (EF 0,01 kg N₂O-N/kg N × 44/28 × GWP 265) (2006) | TO BE VALIDATED |
| QUEIMA_RESIDUOS_AGRO | 0,003 | tCO₂e/tonelada queimada | IPCC 2006 Tier 1 — queima de resíduos agrícolas (CH₄ + N₂O; CO₂ biogênico não contabilizado) (2006) | TO BE VALIDATED |
| REFRIG_COMERCIAL | 0,35 | tCO₂e/unidade/ano | GWP R-410A DEFRA 2024 (1.924 kgCO₂e/kg, AR5) × carga ~1,2 kg × fuga anual 15% ≈ 0,35 t — premissas documentadas (2024) | OFFICIAL |
Table generated automatically from the single source of factors (factors.js), the same values used by the calculator. Factors marked “to be validated” or “estimate” will be validated in Round 2.
Calculation formulas
The +15% safety margin is applied to the sum of categories to account for the uncertainty inherent in screening estimates.
DQS — DoubleDyn Quality Score
DQS (DoubleDyn Quality Score, 0–1000) is the proprietary indicator of an operation's environmental evidence quality, completeness and traceability, from event to project. Four weighted criteria (total = 1000): the more complete and verifiable the evidence, the higher the score. This is neither regulatory nor third-party certification; it is DoubleDyn's transparency layer over what was measured and evidenced.
- Documented weights: Registry 300 points (30%) · Evidence 250 points (25%) · Data 250 points (25%) · Methodology 200 points (20%)
- Registry (0–300): verifiable public evidence — on-chain retirement in the beneficiary's name + DD-CERT certificate with QR and serial (300) · on-chain retirement without a certificate (200) · off-chain retirement receipt (80)
- Evidence (0–250): documentation for every figure — complete dossier with original procurement, contract and reports (250) · partial documents with specific gaps (150) · undocumented figures (30)
- Data (0–250): actual measurement vs estimates — measured primary data (bills, telemetry, volume estimation) (250) · estimate with documented assumptions (150) · sector/CNAE proxy estimate (80)
- Methodology (0–200): method and factors from official sources — documented GHG Protocol + MCTI/SIRENE, DEFRA, IPCC factors (200) · proprietary method without external references (100) · no declared method (0)
- Confidence factor: proxy-estimated data (CNAE) applies 0.92, an 8% methodological uncertainty penalty
- DQS = (registry + evidence + data + methodology) × confidence factor, capped between 0 and 1000
- Calculator Quick Scan: the preview uses only Data + Methodology (maximum 450) and is labelled self-declared. An operation's official DQS requires actual evidence and records and is granted after execution.
| Seal | DQS range |
|---|---|
| Gold | ≥ 751 |
| Silver | 401 – 750 |
| Bronze | ≤ 400 |
Sector benchmarks (intensity)
Average intensity in tCO₂e per R$ 1 million of annual revenue, by sector. Based on public national inventory data (SEEG / GHG Protocol Brazil).
| Sector | Intensity (tCO₂e/R$ million) |
|---|---|
| Agriculture | 120 |
| Mining | 180 |
| Industry | 85 |
| Logistics | 110 |
| Construction | 75 |
| Services | 12 |
| Retail and trade | 25 |
| Other | 60 |
Limitations
- Estimates based on national averages and sector benchmarks may differ from the company's specific circumstances.
- Scopes and factors are simplified for screening; Scope 3 classification is approximate.
- Does not replace a formal inventory (GHG Protocol / ISO 14064) or regulatory reporting (SBCE/CVM).
- The +15% margin covers estimate uncertainty, not errors in reported data.
- Factors are reviewed periodically; version and review date are published above.
under continuous validation — Electricity: MCTI 2025 (explicit base year). For a formal inventory, use the factor for the reporting year (e.g. 2024 → 0.0545).